SELECTION OF FLOW METER AT LNG SERVICE
LNG Metering Skid
Natural gas (NG) has become an important part of the energy
mix, particularly in electric power generation, where it’s prized as an easily
handled, clean-burning liquid. Liquefied Natural Gas (LNG) is a more
cost-effective way to bring gas to market across oceans and continents.
Construction of many overland pipe-lines is underway, but gas companies are
also investing in LNG supply chains, building massive LNG tankers to convey gas
from port to port, and terminals to convert gas to its form for easy transport,
and back to gas for consumption. In this Paper, we’ll analyze the challenges of
Flow measurement at LNG service applications.
Labels: coriolis, flow control, flow measurement, flow meter, lng metering, ultrasonic flow meter
Sunday, July 8, 2012
Flow Measurement - 4
EPC-School 2012
I for Instrumentation
I for Instrumentation
Ultra Sound Flow Meter
Ultrasonic flow meters can be used on wide range of fluids,
i.e. liquids, gases and steam. The “transit –time” or “time-of-flight” meters
are basically “time-difference” meters, as they are based on time difference measurement
of acoustic waves that are transmitted in opposite directions through the flow.
The time difference is directly proportional to flow rate.
Labels: flow meter, mass flow meter, Rahul Kapoor, time of flight meter, time-difference flow meter, time-transit flowmeter, ultrasonic, ultrasonic flow meter, ultrasound flow meter
Thursday, July 5, 2012
Flow Measurement-2
Labels: coriolis, coriolis force, coriolis forces, custody transfer meter, density measurement, flow meter, mass flow meter, micro motion, Rahul Kapoor